Programmable DC Power Supply
Highly Precise Single CH Output
Model: OPS Series

OPS Series offers next generation highly precise, highly responsive Programmable DC Power Supply that enables simple operation method, precise DC output, diverse PC applications, strong durability and diverse circuits for protection. Likewise, this product can be used at various places in the digital era including industrial fields, research centers, educational institutions etc.

1 Over Voltage Protection Key
2  Over Current Protection Key
3 I/O CONFIG or LOCAL Key
4 LOCK Key
5 Store current state or Calibration Key
6 Recall Key of stored memory
7 Output voltage/ current ON/ OFF
8 Voltage/ current selection or Limit Display Key
9 Key for setting up the cycling mode STEP
10 Key for controlling cycling mode SEQUENCE
11 Key for setting up repetition of the cycling mode
12 Cycling mode RUN/STOP Key
13 Error message Display Key
14 Menu Escape Key
15 Voltage/ Current Cursor
A Power switch
B Display for indication
C Adjustment encoder
D Output terminal

 

Protection against over-voltage (OVP) / over current (OCP)
Able to store and recall up to 10 operation states (voltage, current, OVP, OCP)
Able to store and confirm up to 10 error messages
Self-diagnosis test mode
Supports up to 100 cycling modes (voltage, current slope and delay time)
Support for external software calibration without inside calibration.
Factory function provided (memory initialization and correction date back-up and recovery)
Let’s use the powerful store function!

OPS Series can store and recall up to 10 voltage and current, OVP, OCP that the user sets up. Even when a user is not an engineer, the user can use it for the production and product inspection, reliability test with the function for recalling the pre-set and stored data.

How does our company productivity rank in the industry?

Our Programmable DC Power Supply is ideal for the FA system development since it can judge at least 30 equipments whether they are pass or fail within one second. It is possible to provide fine and precise source one using this product alone, since it has built-in 24 bit ADC. Likewise, it measures even the fine voltage and electric current. Thus, it is possible to reduce budget since it does not require separate voltage/ current measurement device at the outside.

Experience the upgraded stability

Even when the equipment internal temperature changes or even when there are external factors that influence while conducting test for a long time due to the Temperature Compensation Circuit and real-time measurement Compensation Circuit that are applied to the OPS Series, it is possible to conduct test in an accurate and stable manner while maintaining the set up voltage.

Now, use it with peace of mind. [Protection Mode]

Using the over-voltage (O.V.P) and over-current (O.C.P)mode that are built in the OPS Series blocks the output over-voltage or over-current to protect the source of over-load, and it can be used safely even in case of user negligence or when conducting test for a long time. Moreover, it is possible to reduce the defect rate of the production line by blocking malfunction caused by user negligence.

Detail description
Why? Why is the output voltage different from the set up voltage?

Remote Voltage Sensing
Power supplier that does not provide V-Sensing may not offer an accuracy level that a user wants. ODA Technologies Programmable DC Power Supply provides V-Sensing (Remote Voltage Sensing) function to produce compensation output when it comes to the voltage that is damaged due to the cable specific resistance property in order to supply increasingly precise power.

Now, measure immediately without delay after the output setting!

Competitors products require delay for a specific period of time in order to obtain accurate measurement value after the setting order is communicated. Even when the order for setting is communicated, Analog Controller responsiveness is late. Thus, error may result in which measurement takes place while output voltage is increasing. Meanwhile, it is necessary to collect data impeccably only when measurement takes place after waiting for the setting of the output voltage and electric current is completed. Our company¡¯s programmable power supply can work with 2 ms to conduct 15 V setting in the 0V.

The work can be carried out even when there is no program developer present.

Cycling Mode TEST!
Cycling Mode that is provided to the OPS Series provides memory so that up to 100 gradient and maintenance time of the voltage, electric current can be stored. When cycling Mode is used, it is possible to develop the system for the long-time reliability test for the product with ease without producing the Windows Application. Moreover, it is possible for the voltage and electric current to supply powers that are different in a regular, consistent manner to the mechanical device and facility besides the reliability test.

Pyramidal wave materialization

It is possible to materialize the output of the pyramidal wave by receiving the Arbitrary Function Generator¡¯s input voltage with the Analog Input.

Specification
    Voltage
Current
1A 2A 3A 5A 10A 30A 50A 100A 200A 500A
9V OPS-91 OPS-92 OPS-93 OPS-95 OPS-910 OPS-930 OPS-950 OPS-9100 OPS-9200 OPS-9500
18V OPS-181 OPS-182 OPS-183 OPS-185 OPS-1810 OPS-1830 OPS-1850 OPS-18100 OPS-18200 OPS-18500
30V OPS-301 OPS-302 OPS-303 OPS-305 OPS-3010 OPS-3030 OPS-3050 OPS-30100 OPS-18200 OPS-30500
50V OPS-501 OPS-502 OPS-503 OPS-505 OPS-5010 OPS-503 OPS-5050 OPS-50100 OPS-50200 OPS-50500
80V OPS-801 OPS-802 OPS-803 OPS-805 OPS-8010 0OPS-8030 OPS-8050 OPS-80100 OPS-80200 OPS-80500
100V OPS-1001 OPS-1002 OPS-1003 OPS-1005 OPS-10010 OPS-10030 OPS-10050 OPS-100100 OPS-100200 OPS-100500
150V OPS-1501 OPS-1502 OPS-1503 OPS-1505 OPS-15010 OPS-15030 OPS-15050 OPS-150100 OPS-150200 OPS-150500
200V OPS-2001 OPS-2002 OPS-2003 OPS-2005 OPS-20010 OPS-20030 OPS-20050 OPS-200100 OPS-200200 OPS-200500
300V OPS-3001 OPS-3002 OPS-3003 OPS-3005 OPS-30010 OPS-30030 OPS-30050 OPS-300100 OPS-300200 OPS-300500
500V OPS-5001 OPS-5002 OPS-5003 OPS-5005 OPS-50010 OPS-50030 OPS-50050 OPS-500100 OPS-500200 OPS-500500

 

                 Parameter
Model
OPS-303 OPS-305 OPS-307 OPS-3010
Output rating 0~30V, 0~3A 0~30V, 0~5A 0~30V, 0~7A 0~30V, 0~10A
Resolution
Programming/Readback ≤ 250uV /≤ 30uA ≤ 250uV /≤ 50uA ≤ 250uV / ≤ 70uA ≤ 250uA / ≤ 100uA
Display Meter 1mV / 100uA 1mV / 100uA 1mV / 1mA 1mV / 1mA
Programming Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 10mV 0.05% + 10mV 0.05% + 10mV 0.05% + 10mV
Current 0.15% + 5mA 0.15% + 5mA 0.2% + 10mA 0.2% + 10mA
Read-back Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 5mV 0.05% + 5mV 0.05% + 5mV 0.05% + 5mV
Current 0.08% + 3mA 0.08% + 3mA 0.15% + 5mA 0.15% + 5mA
Ripple & Noise ≤ 2mVp-p, ≤ 2mArms ≤ 2mVp-p, ≤ 2mArms ≤ 2mVp-p, ≤ 2mArms ≤ 2mVp-p, ≤ 2mArms
Load Regulation 2mV, 500uA 2mV, 500uA 2mV, 500uA 2mV, 500uA
Line Regulation 500uV, 500uA 500uV, 500uA 500uV, 500uA 500uV, 1mA
Command Processing Time <32ms <32ms <32ms <32ms
Voltage Programming Speed(No load)
Rising time ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms
Falling time ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms
Transient Response time Less than 50us for output to recover to within 15mV following a change in output current from full load to half load or vice versa

 

                 Parameter
Model
OPS-503 OPS-505 OPS-801 OPS-802
Output rating 0~50V, 0~3A 0~50V, 0~5A 0~80V, 0~1A 0~80V, 0~2A
Resolution
Programming/Readback ≤ 500uV /≤ 30uA ≤ 500uV /≤ 50uA ≤ 800uV /≤ 10uA ≤ 800uV /≤ 20uA
Display Meter 1mV / 100uA 1mV / 100uA 10mV / 100uA 10mV / 100uA
Programming Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 12mV 0.05% + 12mV 0.05% + 35mV 0.05% + 35mV
Current 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA
Read-back Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 6mV 0.05% + 6mV 0.05% + 18mV 0.05% + 18mV
Current 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA
Ripple & Noise ≤ 3mVp-p, ≤ 2mArms ≤ 3mVp-p, ≤ 2mArms ≤ 6mVp-p, ≤ 2mArms ≤ 6mVp-p, ≤ 2mArms
Load Regulation 2mV, 500uA 2mV, 500uA 3mV, 500uA 3mV, 500uA
Line Regulation 500uV, 500uA 500uV, 500uA 1mV, 500uA 1mV, 500uA
Command Processing Time <32ms <32ms <32ms <32ms
Voltage Programming Speed(No load)
Rising time ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms
Falling time ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms
Transient Response time Less than 50us for output to recover to within 15mV following a change in output current from full load to half load or vice versa
Common matters RS-232C attached by default
19inch half x 3U size : 213mm(W) x 132mm(H) x 370mm(D) (Excepted bumper, less than 300W)
Option Output at the rear side, input power (AC 100, AC 110, AC 230), GPIB communication, GPIB Cable, RS-232C Cable, Analog Signal Input, Analog Signal Output, rack mount kit

 

                 Parameter
Model
OPS-803 OPS-1001 OPS-1002 OPS-1003
Output rating 0~80V, 0~3A 0~100V, 0~1A 0~100V, 0~2A 0~100V, 0~3A
Resolution
Programming/Readback ≤ 800uV /≤ 30uA ≤ 1mV /≤ 10uA ≤ 1mV / ≤ 20uA ≤ 1mV /≤ 30uA
Display Meter 10mV / 100uA 10mV / 100uA 10mV / 100uA 10mV / 100uA
Programming Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 35mV 0.05% + 40mV 0.05% + 40mV 0.05% + 40mV
Current 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA
Read-back Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 18mV 0.05% + 20mV 0.05% + 20mV 0.05% + 20mV
Current 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA
Ripple & Noise ≤ 6mVp-p, ≤ 2mArms ≤ 0.01%mVrms, ≤3mArms ≤0.01%mVrms, ≤3mArms ≤0.01%mVrms, ≤3mArms
Load Regulation 3mV, 500uA 3mV, 500uA 3mV, 500uA 3mV, 500uA
Line Regulation 1mV, 500uA 1mV, 500uA 1mV, 500uA 1mV, 500uA
Command Processing Time <32ms <32ms <32ms <32ms
Voltage Programming Speed(No load)
Rising time ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms
Falling time ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms
Transient Response time Less than 50us for output to recover to within 15mV following a change in output current from full load to half load or vice versa

 

                 Parameter
Model
OPS-1501 OPS-1502 OPS-2001 OPS-3001
Output rating 0~150V, 0~1A 0~150V, 0~2A 0~200V, 0~1A 0~300V, 0~1A
Resolution
Programming/Readback ≤ 1.5mV /≤ 10uA ≤ 1.5mV /≤ 20uA ≤ 2mV /≤ 10uA ≤ 3mV /≤ 10uA
Display Meter 10mV / 100uA 10mV / 100uA 10mV / 100uA 10mV / 100uA
Programming Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 50mV 0.05% + 50mV 0.05% + 75mV 0.05% + 95mV
Current 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA
Read-back Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 25mV 0.05% + 25mV 0.05% + 40mV 0.05% + 50mV
Current 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA
Ripple & Noise ≤ 0.01%mVrms, ≤3mArms ≤ 0.01%mVrms, ≤3mArms ≤ 0.01%mVrms, ≤3mArms ≤ 0.01%mVrms, ≤3mArms
Load Regulation 4mV, 500uA 4mV, 500uA 4mV, 500uA 4mV, 500uA
Line Regulation 1mV, 500uA 1mV, 500uA 1mV, 500uA 1mV, 500uA
Command Processing Time <32ms <32ms <32ms <32ms
Voltage Programming Speed(No load)
Rising time ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms
Falling time ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms
Transient Response time Less than 50us for output to recover to within 15mV following a change in output current from full load to half load or vice versa
Common matters RS-232C attached by default
19inch half x 3U size : 213mm(W) x 132mm(H) x 370mm(D) (Excepted bumper, less than 300W)
Option Output at the rear side, input power (AC 100, AC 110, AC 230), GPIB communication, GPIB Cable, RS-232C Cable, Analog Signal Input, Analog Signal Output, rack mount kit

Product Description

OPS Series offers next generation highly precise, highly responsive Programmable DC Power Supply that enables simple operation method, precise DC output, diverse PC applications, strong durability and diverse circuits for protection. Likewise, this product can be used at various places in the digital era including industrial fields, research centers, educational institutions etc.

1 Over Voltage Protection Key
2  Over Current Protection Key
3 I/O CONFIG or LOCAL Key
4 LOCK Key
5 Store current state or Calibration Key
6 Recall Key of stored memory
7 Output voltage/ current ON/ OFF
8 Voltage/ current selection or Limit Display Key
9 Key for setting up the cycling mode STEP
10 Key for controlling cycling mode SEQUENCE
11 Key for setting up repetition of the cycling mode
12 Cycling mode RUN/STOP Key
13 Error message Display Key
14 Menu Escape Key
15 Voltage/ Current Cursor
A Power switch
B Display for indication
C Adjustment encoder
D Output terminal

 

Protection against over-voltage (OVP) / over current (OCP)
Able to store and recall up to 10 operation states (voltage, current, OVP, OCP)
Able to store and confirm up to 10 error messages
Self-diagnosis test mode
Supports up to 100 cycling modes (voltage, current slope and delay time)
Support for external software calibration without inside calibration.
Factory function provided (memory initialization and correction date back-up and recovery)
Let’s use the powerful store function!

OPS Series can store and recall up to 10 voltage and current, OVP, OCP that the user sets up. Even when a user is not an engineer, the user can use it for the production and product inspection, reliability test with the function for recalling the pre-set and stored data.

How does our company productivity rank in the industry?

Our Programmable DC Power Supply is ideal for the FA system development since it can judge at least 30 equipments whether they are pass or fail within one second. It is possible to provide fine and precise source one using this product alone, since it has built-in 24 bit ADC. Likewise, it measures even the fine voltage and electric current. Thus, it is possible to reduce budget since it does not require separate voltage/ current measurement device at the outside.

Experience the upgraded stability

Even when the equipment internal temperature changes or even when there are external factors that influence while conducting test for a long time due to the Temperature Compensation Circuit and real-time measurement Compensation Circuit that are applied to the OPS Series, it is possible to conduct test in an accurate and stable manner while maintaining the set up voltage.

Now, use it with peace of mind. [Protection Mode]

Using the over-voltage (O.V.P) and over-current (O.C.P)mode that are built in the OPS Series blocks the output over-voltage or over-current to protect the source of over-load, and it can be used safely even in case of user negligence or when conducting test for a long time. Moreover, it is possible to reduce the defect rate of the production line by blocking malfunction caused by user negligence.

Detail description
Why? Why is the output voltage different from the set up voltage?

Remote Voltage Sensing
Power supplier that does not provide V-Sensing may not offer an accuracy level that a user wants. ODA Technologies Programmable DC Power Supply provides V-Sensing (Remote Voltage Sensing) function to produce compensation output when it comes to the voltage that is damaged due to the cable specific resistance property in order to supply increasingly precise power.

Now, measure immediately without delay after the output setting!

Competitors products require delay for a specific period of time in order to obtain accurate measurement value after the setting order is communicated. Even when the order for setting is communicated, Analog Controller responsiveness is late. Thus, error may result in which measurement takes place while output voltage is increasing. Meanwhile, it is necessary to collect data impeccably only when measurement takes place after waiting for the setting of the output voltage and electric current is completed. Our company¡¯s programmable power supply can work with 2 ms to conduct 15 V setting in the 0V.

The work can be carried out even when there is no program developer present.

Cycling Mode TEST!
Cycling Mode that is provided to the OPS Series provides memory so that up to 100 gradient and maintenance time of the voltage, electric current can be stored. When cycling Mode is used, it is possible to develop the system for the long-time reliability test for the product with ease without producing the Windows Application. Moreover, it is possible for the voltage and electric current to supply powers that are different in a regular, consistent manner to the mechanical device and facility besides the reliability test.

Pyramidal wave materialization

It is possible to materialize the output of the pyramidal wave by receiving the Arbitrary Function Generator¡¯s input voltage with the Analog Input.

Specification
    Voltage
Current
1A 2A 3A 5A 10A 30A 50A 100A 200A 500A
9V OPS-91 OPS-92 OPS-93 OPS-95 OPS-910 OPS-930 OPS-950 OPS-9100 OPS-9200 OPS-9500
18V OPS-181 OPS-182 OPS-183 OPS-185 OPS-1810 OPS-1830 OPS-1850 OPS-18100 OPS-18200 OPS-18500
30V OPS-301 OPS-302 OPS-303 OPS-305 OPS-3010 OPS-3030 OPS-3050 OPS-30100 OPS-18200 OPS-30500
50V OPS-501 OPS-502 OPS-503 OPS-505 OPS-5010 OPS-503 OPS-5050 OPS-50100 OPS-50200 OPS-50500
80V OPS-801 OPS-802 OPS-803 OPS-805 OPS-8010 0OPS-8030 OPS-8050 OPS-80100 OPS-80200 OPS-80500
100V OPS-1001 OPS-1002 OPS-1003 OPS-1005 OPS-10010 OPS-10030 OPS-10050 OPS-100100 OPS-100200 OPS-100500
150V OPS-1501 OPS-1502 OPS-1503 OPS-1505 OPS-15010 OPS-15030 OPS-15050 OPS-150100 OPS-150200 OPS-150500
200V OPS-2001 OPS-2002 OPS-2003 OPS-2005 OPS-20010 OPS-20030 OPS-20050 OPS-200100 OPS-200200 OPS-200500
300V OPS-3001 OPS-3002 OPS-3003 OPS-3005 OPS-30010 OPS-30030 OPS-30050 OPS-300100 OPS-300200 OPS-300500
500V OPS-5001 OPS-5002 OPS-5003 OPS-5005 OPS-50010 OPS-50030 OPS-50050 OPS-500100 OPS-500200 OPS-500500

 

                 Parameter
Model
OPS-303 OPS-305 OPS-307 OPS-3010
Output rating 0~30V, 0~3A 0~30V, 0~5A 0~30V, 0~7A 0~30V, 0~10A
Resolution
Programming/Readback ≤ 250uV /≤ 30uA ≤ 250uV /≤ 50uA ≤ 250uV / ≤ 70uA ≤ 250uA / ≤ 100uA
Display Meter 1mV / 100uA 1mV / 100uA 1mV / 1mA 1mV / 1mA
Programming Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 10mV 0.05% + 10mV 0.05% + 10mV 0.05% + 10mV
Current 0.15% + 5mA 0.15% + 5mA 0.2% + 10mA 0.2% + 10mA
Read-back Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 5mV 0.05% + 5mV 0.05% + 5mV 0.05% + 5mV
Current 0.08% + 3mA 0.08% + 3mA 0.15% + 5mA 0.15% + 5mA
Ripple & Noise ≤ 2mVp-p, ≤ 2mArms ≤ 2mVp-p, ≤ 2mArms ≤ 2mVp-p, ≤ 2mArms ≤ 2mVp-p, ≤ 2mArms
Load Regulation 2mV, 500uA 2mV, 500uA 2mV, 500uA 2mV, 500uA
Line Regulation 500uV, 500uA 500uV, 500uA 500uV, 500uA 500uV, 1mA
Command Processing Time <32ms <32ms <32ms <32ms
Voltage Programming Speed(No load)
Rising time ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms
Falling time ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms
Transient Response time Less than 50us for output to recover to within 15mV following a change in output current from full load to half load or vice versa

 

                 Parameter
Model
OPS-503 OPS-505 OPS-801 OPS-802
Output rating 0~50V, 0~3A 0~50V, 0~5A 0~80V, 0~1A 0~80V, 0~2A
Resolution
Programming/Readback ≤ 500uV /≤ 30uA ≤ 500uV /≤ 50uA ≤ 800uV /≤ 10uA ≤ 800uV /≤ 20uA
Display Meter 1mV / 100uA 1mV / 100uA 10mV / 100uA 10mV / 100uA
Programming Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 12mV 0.05% + 12mV 0.05% + 35mV 0.05% + 35mV
Current 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA
Read-back Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 6mV 0.05% + 6mV 0.05% + 18mV 0.05% + 18mV
Current 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA
Ripple & Noise ≤ 3mVp-p, ≤ 2mArms ≤ 3mVp-p, ≤ 2mArms ≤ 6mVp-p, ≤ 2mArms ≤ 6mVp-p, ≤ 2mArms
Load Regulation 2mV, 500uA 2mV, 500uA 3mV, 500uA 3mV, 500uA
Line Regulation 500uV, 500uA 500uV, 500uA 1mV, 500uA 1mV, 500uA
Command Processing Time <32ms <32ms <32ms <32ms
Voltage Programming Speed(No load)
Rising time ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms
Falling time ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms
Transient Response time Less than 50us for output to recover to within 15mV following a change in output current from full load to half load or vice versa
Common matters RS-232C attached by default
19inch half x 3U size : 213mm(W) x 132mm(H) x 370mm(D) (Excepted bumper, less than 300W)
Option Output at the rear side, input power (AC 100, AC 110, AC 230), GPIB communication, GPIB Cable, RS-232C Cable, Analog Signal Input, Analog Signal Output, rack mount kit

 

                 Parameter
Model
OPS-803 OPS-1001 OPS-1002 OPS-1003
Output rating 0~80V, 0~3A 0~100V, 0~1A 0~100V, 0~2A 0~100V, 0~3A
Resolution
Programming/Readback ≤ 800uV /≤ 30uA ≤ 1mV /≤ 10uA ≤ 1mV / ≤ 20uA ≤ 1mV /≤ 30uA
Display Meter 10mV / 100uA 10mV / 100uA 10mV / 100uA 10mV / 100uA
Programming Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 35mV 0.05% + 40mV 0.05% + 40mV 0.05% + 40mV
Current 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA
Read-back Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 18mV 0.05% + 20mV 0.05% + 20mV 0.05% + 20mV
Current 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA
Ripple & Noise ≤ 6mVp-p, ≤ 2mArms ≤ 0.01%mVrms, ≤3mArms ≤0.01%mVrms, ≤3mArms ≤0.01%mVrms, ≤3mArms
Load Regulation 3mV, 500uA 3mV, 500uA 3mV, 500uA 3mV, 500uA
Line Regulation 1mV, 500uA 1mV, 500uA 1mV, 500uA 1mV, 500uA
Command Processing Time <32ms <32ms <32ms <32ms
Voltage Programming Speed(No load)
Rising time ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms
Falling time ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms
Transient Response time Less than 50us for output to recover to within 15mV following a change in output current from full load to half load or vice versa

 

                 Parameter
Model
OPS-1501 OPS-1502 OPS-2001 OPS-3001
Output rating 0~150V, 0~1A 0~150V, 0~2A 0~200V, 0~1A 0~300V, 0~1A
Resolution
Programming/Readback ≤ 1.5mV /≤ 10uA ≤ 1.5mV /≤ 20uA ≤ 2mV /≤ 10uA ≤ 3mV /≤ 10uA
Display Meter 10mV / 100uA 10mV / 100uA 10mV / 100uA 10mV / 100uA
Programming Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 50mV 0.05% + 50mV 0.05% + 75mV 0.05% + 95mV
Current 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA 0.15% + 5mA
Read-back Accuracy (@25c ±5c)±(%of output + offset)
Voltage 0.05% + 25mV 0.05% + 25mV 0.05% + 40mV 0.05% + 50mV
Current 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA 0.08% + 3mA
Ripple & Noise ≤ 0.01%mVrms, ≤3mArms ≤ 0.01%mVrms, ≤3mArms ≤ 0.01%mVrms, ≤3mArms ≤ 0.01%mVrms, ≤3mArms
Load Regulation 4mV, 500uA 4mV, 500uA 4mV, 500uA 4mV, 500uA
Line Regulation 1mV, 500uA 1mV, 500uA 1mV, 500uA 1mV, 500uA
Command Processing Time <32ms <32ms <32ms <32ms
Voltage Programming Speed(No load)
Rising time ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms ≤ 7.5V/ms
Falling time ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms ≤ 3V/ms
Transient Response time Less than 50us for output to recover to within 15mV following a change in output current from full load to half load or vice versa
Common matters RS-232C attached by default
19inch half x 3U size : 213mm(W) x 132mm(H) x 370mm(D) (Excepted bumper, less than 300W)
Option Output at the rear side, input power (AC 100, AC 110, AC 230), GPIB communication, GPIB Cable, RS-232C Cable, Analog Signal Input, Analog Signal Output, rack mount kit