+6012-2100 344


Name:   Password:

Products

DQ1000 Series  LOGIC ANALYZER, OSCILLOSCOPE & MULTIMETER

ENQUIRY




Download Brochure

Mixed Signal Oscilloscope
Model : DQ1000C Series

Features

.Support logic analyzer and multimeter
.2GSa/s sampling rate and 50GSa/s equivalent sampling rate
.1024k channel memory depth
.5.7-inch color LCD display
.USB-host/device and option LAN, GPIB interface

Technical Data DQ1042C DQ1062C DQ1102C DQ1152C DQ1202C
Channels 2 external + logical analyzer + multimeter
Sampling rate 2GSa/s
Equivalent sampling rate 50GSa/s
Display
Type 5.7″ rectangle color LCD
Backlight intensity 300 ni
Display resolution 320 horizontal x 240 vertical pixels

Vertical system

Sensitivity and accuracy 1mV/div~10V/div
Vertical resolution 8 bit
Width of band (-3dB) DC (AC 5Hz)
~ 40MHz
DC (AC 5Hz)
~ 60MHz
DC (AC 5Hz)
~ 100MHz
DC (AC 5Hz)
~ 150MHz
DC (AC 5Hz)
~ 200MHz
Selectable analog
bandwidth limit
20MHz
Rise time ≤8.7ns ≤5.8ns ≤3.5ns ≤2.3ns ≤1.8ns
DC gain Accuracy ±5%(1mV/div) ±4%(2mV/div) ±3%(5mV/div~10V/div)
DC measurement accuracy ±(5%+0.1div)(1mV/div) ±(5%+0.1div)(1mV/div) ±(5%+0.1div)(1mV/div)

Horizontal system

SEC/DIV range 2ns~50s/div(200MHz, 150MHz)
5ns~50ns/div(100MHz~40MHz), at 1-2-5 increment
Waveform interpolation Sin(x)/x
Recording length 1024k
Sampling rate and delay
time accuracy
±50ppm (any time interval 1ms)
Delta time
measurement accuracy
Single: ±(1 sampling time interval + 50ppm rdg. + 0.6ns)
Average values: ±(1 sampling time interval + 50ppm rdg. + 0.4ns)

Trigger system

Mode Auto, normal, single
Type Edge, pulse, video, alternate
Hold off range 100ns~1.5s

Math

+, -, x, ÷
FFT
Acquire input
Input coupling DC, GND, AC
Input impedance 1MΩ±1.5% 24pF±3pF
Probe attenuation 1x, 10x, 100x, 1000x
Max. input voltage 400V (DC+AC peak)
Measurement
Cursor Voltage difference ( V) between cursors
Time difference ( T) between cursors
Reciprocal of T in Hz (1/ T)
Auto-measure Vrms, Vavg, Vp-p, Vmax, Vmin, Vtop, Vhigh, Vlow, Vmid, Vamp;
Period, Freq, Rise, Fall, +Width, -Width, +Duty, -Duty, Delay
I/O
Standard USB(D), USB(H)
Options GPIB, LAN
Calibrator
Output voltage 3V(≥1MΩ load)
Output frequency 1kHz
Logical analyzer
Input channel 200MSa/s
Max. sampling rate D0~D15
Recording length 512k
Max. input voltage ±40Vpeak
Minimum voltage slew 1.2Vpp
Trigger mode Code D0~D15
Trigger code: H, L, X
Clock edge: Rise, Fall
Persist D0~D15
Trigger code: H, L, X
Condition: >, <, =
Persist setup: 20ns~10s

Digital multimeter characterizes

DC voltage Range 400.0mV/4.000V/40.00V/400.0V
Accuracy ±(1%+5digits)
AC voltage (40Hz~400Hz) Range 400.0mV/4.000V/40.00V/400.0V
Accuracy ±(1.2%+5digits)
Resistance Range 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ
Accuracy ±(1.5%+5digits)
On/off <70.0Ω
Diode Forward voltage drop 0.5~0.8V
DC current Range 4mA/40mA/400mA
Accuracy ±(1%+5digits)
Range 4A
Accuracy ±(1.5%+5digits)
Power source 100~240VACrms, 45~440Hz; 50VA Max; CAT II
Dimensions (Wx Hx D) 320mm x 150mm x 130mm
Weight 2.5kg
Accessories Operation manual, adapter, probex 2, multimeter penx2, current-voltage convertor modulex 2

Product Description

Features

.Support logic analyzer and multimeter
.2GSa/s sampling rate and 50GSa/s equivalent sampling rate
.1024k channel memory depth
.5.7-inch color LCD display
.USB-host/device and option LAN, GPIB interface

Technical Data DQ1042C DQ1062C DQ1102C DQ1152C DQ1202C
Channels 2 external + logical analyzer + multimeter
Sampling rate 2GSa/s
Equivalent sampling rate 50GSa/s
Display
Type 5.7″ rectangle color LCD
Backlight intensity 300 ni
Display resolution 320 horizontal x 240 vertical pixels

Vertical system

Sensitivity and accuracy 1mV/div~10V/div
Vertical resolution 8 bit
Width of band (-3dB) DC (AC 5Hz)
~ 40MHz
DC (AC 5Hz)
~ 60MHz
DC (AC 5Hz)
~ 100MHz
DC (AC 5Hz)
~ 150MHz
DC (AC 5Hz)
~ 200MHz
Selectable analog
bandwidth limit
20MHz
Rise time ≤8.7ns ≤5.8ns ≤3.5ns ≤2.3ns ≤1.8ns
DC gain Accuracy ±5%(1mV/div) ±4%(2mV/div) ±3%(5mV/div~10V/div)
DC measurement accuracy ±(5%+0.1div)(1mV/div) ±(5%+0.1div)(1mV/div) ±(5%+0.1div)(1mV/div)

Horizontal system

SEC/DIV range 2ns~50s/div(200MHz, 150MHz)
5ns~50ns/div(100MHz~40MHz), at 1-2-5 increment
Waveform interpolation Sin(x)/x
Recording length 1024k
Sampling rate and delay
time accuracy
±50ppm (any time interval 1ms)
Delta time
measurement accuracy
Single: ±(1 sampling time interval + 50ppm rdg. + 0.6ns)
Average values: ±(1 sampling time interval + 50ppm rdg. + 0.4ns)

Trigger system

Mode Auto, normal, single
Type Edge, pulse, video, alternate
Hold off range 100ns~1.5s

Math

+, -, x, ÷
FFT
Acquire input
Input coupling DC, GND, AC
Input impedance 1MΩ±1.5% 24pF±3pF
Probe attenuation 1x, 10x, 100x, 1000x
Max. input voltage 400V (DC+AC peak)
Measurement
Cursor Voltage difference ( V) between cursors
Time difference ( T) between cursors
Reciprocal of T in Hz (1/ T)
Auto-measure Vrms, Vavg, Vp-p, Vmax, Vmin, Vtop, Vhigh, Vlow, Vmid, Vamp;
Period, Freq, Rise, Fall, +Width, -Width, +Duty, -Duty, Delay
I/O
Standard USB(D), USB(H)
Options GPIB, LAN
Calibrator
Output voltage 3V(≥1MΩ load)
Output frequency 1kHz
Logical analyzer
Input channel 200MSa/s
Max. sampling rate D0~D15
Recording length 512k
Max. input voltage ±40Vpeak
Minimum voltage slew 1.2Vpp
Trigger mode Code D0~D15
Trigger code: H, L, X
Clock edge: Rise, Fall
Persist D0~D15
Trigger code: H, L, X
Condition: >, <, =
Persist setup: 20ns~10s

Digital multimeter characterizes

DC voltage Range 400.0mV/4.000V/40.00V/400.0V
Accuracy ±(1%+5digits)
AC voltage (40Hz~400Hz) Range 400.0mV/4.000V/40.00V/400.0V
Accuracy ±(1.2%+5digits)
Resistance Range 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ
Accuracy ±(1.5%+5digits)
On/off <70.0Ω
Diode Forward voltage drop 0.5~0.8V
DC current Range 4mA/40mA/400mA
Accuracy ±(1%+5digits)
Range 4A
Accuracy ±(1.5%+5digits)
Power source 100~240VACrms, 45~440Hz; 50VA Max; CAT II
Dimensions (Wx Hx D) 320mm x 150mm x 130mm
Weight 2.5kg
Accessories Operation manual, adapter, probex 2, multimeter penx2, current-voltage convertor modulex 2