Features. Output off function
. Dual independent adjustable DC outputs.
. Independent, series and parallel variety output
. Constant voltage and constant current
. Low ripple and noise
. Four LED displays with 3 digits, selectable for two sets
output voltage and current display simultaneously
. 16 hours continuous output with full load
. Auto tracking outputSpecifications

Line Regulation: CV ≤5×10-4 + 3mV (M10-QD3010, M10-QD3020, M10-QD6010)

≤1×10-4 + 3mV (other models)

CC ≤4×10-3 + 3mA (M10-QD3010, M10-QD3020, M10-QD6010)
≤2×10-3 + 3mA (other models)
Loading Effect: CV

≤5×10-4 + 3mV (output current>10A)

≤1×10-3+ 3mV (output current>10A)

(M10-QD3010, M10-QD3020, M10-QD6010)

CC

≤1×10-4 + 3mV (output current ≤3A)

≤2×10-4 + 3mV (3A≤ output current <10A)

 (other models)

.Ripple & Noise:

1.5mV (rms) (M10-QD3010, M10-QD3020, M10-QD6010)

1mV (rms) (other models)

.Display Accuracy: ±0.5%Rdg+2digits
.Input Voltage: 110~127VAC±10%, 220~240VAC±10%  Switchable
Model Independent Output Series Output Parallel Output Dimensions
(LxWxD)
Weight (kg)
M10-QD302 CH1/0~30V/0~2A
CH2/0~30V/0~2A
CH1+CH2
0~60V/0~2A
CH1//CH2
0~30V/0~4A
250x135x300mm 8
M10-QD303 CH1/0~30V/0~3A
CH2/0~30V/0~3A
CH1+CH2
0~60V/0~3A
CH1//CH2
0~30V/0~6A
M10-QD305 CH1/0~30V/0~5A
CH2/0~30V/0~5A
CH1+CH2
0~60V/0~5A
CH1//CH2
0~30V/0~10A
M10-QD3010 CH1/0~30V/0~10A
CH2/0~30V/0~10A
CH1+CH2
0~60V/0~10A
CH1//CH2
0~30V/0~20A
250x135x460mm 12
M10-QD3020 CH1/0~30V/0~20A
CH2/0~30V/0~20A
CH1+CH2
0~60V/0~20A
CH1//CH2
0~30V/0~40A
16
M10-QD6010 CH1/0~60V/0~10A
CH2/0~60V/0~10A
CH1+CH2
0~120V/0~10A
CH1//CH2
0~60V/0~20A
16

Product Description

Features. Output off function
. Dual independent adjustable DC outputs.
. Independent, series and parallel variety output
. Constant voltage and constant current
. Low ripple and noise
. Four LED displays with 3 digits, selectable for two sets
output voltage and current display simultaneously
. 16 hours continuous output with full load
. Auto tracking outputSpecifications

Line Regulation: CV ≤5×10-4 + 3mV (M10-QD3010, M10-QD3020, M10-QD6010)

≤1×10-4 + 3mV (other models)

CC ≤4×10-3 + 3mA (M10-QD3010, M10-QD3020, M10-QD6010)
≤2×10-3 + 3mA (other models)
Loading Effect: CV

≤5×10-4 + 3mV (output current>10A)

≤1×10-3+ 3mV (output current>10A)

(M10-QD3010, M10-QD3020, M10-QD6010)

CC

≤1×10-4 + 3mV (output current ≤3A)

≤2×10-4 + 3mV (3A≤ output current <10A)

 (other models)

.Ripple & Noise:

1.5mV (rms) (M10-QD3010, M10-QD3020, M10-QD6010)

1mV (rms) (other models)

.Display Accuracy: ±0.5%Rdg+2digits
.Input Voltage: 110~127VAC±10%, 220~240VAC±10%  Switchable
Model Independent Output Series Output Parallel Output Dimensions
(LxWxD)
Weight (kg)
M10-QD302 CH1/0~30V/0~2A
CH2/0~30V/0~2A
CH1+CH2
0~60V/0~2A
CH1//CH2
0~30V/0~4A
250x135x300mm 8
M10-QD303 CH1/0~30V/0~3A
CH2/0~30V/0~3A
CH1+CH2
0~60V/0~3A
CH1//CH2
0~30V/0~6A
M10-QD305 CH1/0~30V/0~5A
CH2/0~30V/0~5A
CH1+CH2
0~60V/0~5A
CH1//CH2
0~30V/0~10A
M10-QD3010 CH1/0~30V/0~10A
CH2/0~30V/0~10A
CH1+CH2
0~60V/0~10A
CH1//CH2
0~30V/0~20A
250x135x460mm 12
M10-QD3020 CH1/0~30V/0~20A
CH2/0~30V/0~20A
CH1+CH2
0~60V/0~20A
CH1//CH2
0~30V/0~40A
16
M10-QD6010 CH1/0~60V/0~10A
CH2/0~60V/0~10A
CH1+CH2
0~120V/0~10A
CH1//CH2
0~60V/0~20A
16