+6012-2100 344


Name:   Password:

Products

ST-141 & ST-141D 2CH Vibration Meter

ENQUIRY




Download Brochure

Dual Channel Vibration Meter
Model ST-141 & ST-141D

 

 

 

This meter can measure the vibration by the rotator and the reciprocator, as well as the damage of bearings. The items include acceleration, velocity, and displacement; through the meter, you can determine if to repair or renew the machines.

 

 

Features

  • Wide frequency range of 10Hz to 5KHz
  • Acceleration, velocity and displacement measurement
  • Meets ISO2954 sensor for accurate measurement
  • Vibration sensor with magnetic adapter on1.2M (47.2) cable
  • Frequency Lo range :10Hz~1KHz meets ISO 2954 measurement, Hi range : 10Hz~5KHz
  • Stores 99 records manually (ST-140)
  • Record /Recall MIN (ST-141),MAX readings
  • Data logger with 9999 records capacity (ST-140D)
  • USB interface (ST-140D)
  • Offset adjustment used for zero function
  • Auto power off with disable function
  • Resolution:0.1m/s²,0.01g,1ft/s²,0.1mm/s,0.01cm/s,0.01inch/s,0.001mm, 0.001inch

 

 

The environmental temperature range of measurement: 23±3°C

Acceleration ACC (RMS,PEAK,MAX HOLD) 1g =9.81m/s2

Range 0.5~199.9 m/s2 0.05~20.39g 2〜656 ft/s2
Resolution 0.1 m/s² 0.01g 1 ft/s2
Accuracy ±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

Calibration point 50m/s2

(158Hz)

50m/s2 (158Hz) 50m/s2 (158Hz)

 

Velocity VEL (RMS, PEAK, MAX HOLD)

Range 0.5~199.9

mm/s

0.05~19.99cm/s 0.02~7.87

inch/s

Resolution 0.1 mm/s 0.01cm/s 0.01inch/s
Accuracy ±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

Calibration point 50mm/s

(158Hz)

50 mm/s

(158Hz)

50 mm/s

(158Hz)

 

Displacement DISP (P-P, MAX HOLD P-P)

Unit mm inch
Range 0.005~1.999mm 0.002~0.078inch
Resolution 0.001 mm 0.001 inch
Tolerance ±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

Calibration point 0.141mm(158Hz) 0.141mm(158Hz)

Product Description

 

 

 

This meter can measure the vibration by the rotator and the reciprocator, as well as the damage of bearings. The items include acceleration, velocity, and displacement; through the meter, you can determine if to repair or renew the machines.

 

 

Features

  • Wide frequency range of 10Hz to 5KHz
  • Acceleration, velocity and displacement measurement
  • Meets ISO2954 sensor for accurate measurement
  • Vibration sensor with magnetic adapter on1.2M (47.2) cable
  • Frequency Lo range :10Hz~1KHz meets ISO 2954 measurement, Hi range : 10Hz~5KHz
  • Stores 99 records manually (ST-140)
  • Record /Recall MIN (ST-141),MAX readings
  • Data logger with 9999 records capacity (ST-140D)
  • USB interface (ST-140D)
  • Offset adjustment used for zero function
  • Auto power off with disable function
  • Resolution:0.1m/s²,0.01g,1ft/s²,0.1mm/s,0.01cm/s,0.01inch/s,0.001mm, 0.001inch

 

 

The environmental temperature range of measurement: 23±3°C

Acceleration ACC (RMS,PEAK,MAX HOLD) 1g =9.81m/s2

Range 0.5~199.9 m/s2 0.05~20.39g 2〜656 ft/s2
Resolution 0.1 m/s² 0.01g 1 ft/s2
Accuracy ±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

Calibration point 50m/s2

(158Hz)

50m/s2 (158Hz) 50m/s2 (158Hz)

 

Velocity VEL (RMS, PEAK, MAX HOLD)

Range 0.5~199.9

mm/s

0.05~19.99cm/s 0.02~7.87

inch/s

Resolution 0.1 mm/s 0.01cm/s 0.01inch/s
Accuracy ±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

Calibration point 50mm/s

(158Hz)

50 mm/s

(158Hz)

50 mm/s

(158Hz)

 

Displacement DISP (P-P, MAX HOLD P-P)

Unit mm inch
Range 0.005~1.999mm 0.002~0.078inch
Resolution 0.001 mm 0.001 inch
Tolerance ±(5%+5d)

@79.4Hz and158Hz

±(5%+5d)

@79.4Hz and158Hz

Calibration point 0.141mm(158Hz) 0.141mm(158Hz)