Product Description
DQ6000 Series
DIGITAL STORAGE OSCILLOSCOPE
Features
. 500MSa/s~1GSa/s sampling rate
. 7 inch wide rectangle colour LCD
. One key print screen
. 2 x 512k words per channel record length
. FFT function
. Auto-setting for quick setup and waveform acquisition
. Advanced cursor modes: manual, auto and track
TechnicalData | DQ6025 | DQ6052 | DQ6052E | DQ6102E |
Display | ||||
Type | 7″ rectangle color LCD | |||
Backlight intensity | 300cd/m2 | |||
Display resolution | 400 horizontal × 240 vertical pixels | |||
Display contrast | Adjustable | |||
VERTICAL SYSTEM | ||||
Sensitivity and accuracy | 1mV / DIV~20V / DIV | |||
Vertical resolution | 8 bit | |||
Width of band (-3dB) | 25MHz | 50MHz | 50MHz | 100MHz |
Rise time | ≤14ns | ≤7ns | ≤7ns | ≤3.5ns |
Sing-shot band width | 25MHz | 50MHz | 50MHz | 100MHz |
Input coupling | DC , GND , AC | |||
DC gain accuracy | ±5% (1mV/DIV~2mV/DIV), ±4% (5mV/DIV) ±3% (10mV/DIV~20mV/DIV) | |||
Delta voltage Measurement accuracy | ±(3%Rdg+0.05DIV) | |||
HORIZONTAL SYSTEM | ||||
SEC/DIV range | 10ns~50s/DIV | 5ns~50s/DIV | 2ns~50s/DIV | 2ns~50s/DIV |
Sampling rate range | 500M Sa/s | 500M Sa/s | 1G Sa/s | 1G Sa/s |
Wave forn interplation | (Sinx)/x | |||
Record length | 2 x 512k/channel | |||
Memory length | 25k (12.5k per channel) | |||
Sampling rate and delay Time accuracy | ±100ppm over any ≥1mS time interval | |||
Delta time Measurement accuracy | Single ± (1 sampling interval time+ 100ppm x rdg +0.6ns) Average ± (1 sampling interval time+ 50ppm x rdg +0.4ns) |
|||
TRIGGER SYSTEM | ||||
Acquisition Mode | AUTO, Normal, Single | |||
Type | Edge,TV, pulse, Width | |||
Hold Off Range | 80ns~1.5s | |||
MATH | +, -, ×, ÷ | |||
FFT | ||||
ACQUIRE INPUT | ||||
Input couping | DC,AC or GND | |||
Input impedance | 1MΩ±2% 20pF±3pF | |||
Probe attenuation | 1x 10x 100x 1000x | |||
Max.input voltage | 400V (DC + AC peak) at 1KHz or less | |||
Channel CMR | Better than 40:1 | |||
Channel isolation | Better than 40:1 | |||
DISPLAY | ||||
Persist time | 1s, 2s, 5s | |||
STORAGE | Waveform, Setup, Bit | |||
RECORDER | Record, Replay | |||
MEASUREMENT | ||||
Cursor | Voltage difference (∆V) between cursors | |||
Time difference(∆T) between cursors | ||||
Reciprocal of ∆T in Hz (1/∆T) | ||||
AUTO-Mesure | Vrms, Vavg, Vp-p, Vmax, Vmin, Vtop, Vhigh, Vlow, Vmid, Vamp; period, Freq, Rise, Fall, +Width, +Duty, -Duty, Delay |
|||
I/O | ||||
Standard | USB OTG | |||
CALIBRATOR SIGNAL | ||||
Output Voltage | 3V ( ≥1MΩ load) | |||
Output Frequency | 1 kHz | |||
POWER SOURCE | 100/240VACrms, 45Hz~440Hz, 50VaMax; CAT II | |||
ACCESSORIES | One operation manual,Power cord, USB cable, probe2, Software CD-ROM | |||
DIMENSIONS & WEIGHT | 306(W) x 147(H) x 122(D)mm, 2.2kg |