+6012-2100 344


Name:   Password:

Products

GA4063 Digital Spectrum Analyzer

ENQUIRY




Download Brochure

Digital Spectrum Analyzer
GA40XX Series

Product Overview
GA40XX series is a small size, light weight, cost-effective portable spectrum analyzer to meet your all the
RF application demands. It has easy-to-keyboard layout and high-definition 8.5-inch TFT color
LCD display; display contains the appropriate settings and alerts. It includes the standard USB, LAN and
RS232 communication interface, virtual terminal display and control and remote network access.
The spectrum analyzer can be widely applied in many fields of science education, enterprise
research and development and industrial production.

Features
Frequency range 9 kHz to 1.5GHz / 3GHz / 7.5GHz
Displayed average noise level (DANL)
GA4062/GA4032 9KHz~1.5GHz
GA4033/GA4062 9KHz~3GHz
Ga4064 9KHz~7.5GHz

TECHNICAL SPECIFICATIONS
GA4062 GA4032 GA4033 GA4063 GA4064
Frequency Specifications
Frequency range: 9 kHz to 1.5 GHz 9 kHz to 3 GHz 9 kHz to 7.5 GHz
Internal 10 MHz frequency reference accuracy
Initial Calibration accuracy ± 1 x 10 -7
Aging rate: ± 0.1ppm/yr ± 1ppm/year ± 0.1ppm/yr
Temperature stability: ± 5 x 10 -8 ppm – Referenced to frequency reading at 0-50 °C.
Frequency readout accuracy with marker (start, stop, center, marker)
Marker resolution:  (frequency span)/(sweep points -1),
Uncertainty ± (frequency indication × frequency reference uncertainty +1% × span +10% ×resolution bandwidth + marker resolution+1 Hz)
Frequency reference uncertainty = (aging rate x period of time since adjustment + temperature stability).
Marker frequency counter
Resolution 1 Hz
Accuracy ±(marker frequency × frequency reference uncertainty +counter resolution)
(marker level to displayed noise level > 25 dB; frequency offset 0 Hz)
Frequency span
Range 0Hz (zero span), 100 Hz to 3GHz
Resolution 1 Hz
Accuracy ±span/(sweep points -1)
SSB phase noise < -100 dBc/Hz, Carrier offset 100 kHz < -90 dBc/Hz, Carrier offset 10 kHz < -95 dBc/Hz, Carrier offset 10 kHz
(Center frequency 500 MHz, RBW= 100Hz, VBW=1Hz, Operating Temp: 20 °C to 30 °C).
Resolution bandwidth (RBW)
-3 dB bandwidth: 1 Hz to 3 MHz 1 Hz to 1 MHz 1 Hz to 3 MHz
Accuracy: ± 5%, RBW = 10 Hz to 1 MHz Nominal, ±10%, RBW = 3 MHz
Resolution filter shape factor < 5 : 1
Video bandwidth (VBW)
-3 dB bandwidth 1 Hz to 3 MHz, 1-3-10 sequence
Amplitude
Measurement range +30dBm to displayed average noise level (DANL)
Input attenuator range 0 dB to 50 dB, in 10 dB steps.
Maximum safe input level
Average continuous power +30 dBm, (3 minutes maximum, Input attenuator≥20 dB, preamplifier off
DC voltage ± 50 VDC maximum ± 25 VDC maximum
Displayed average noise level
Preamp off ≤- 148dBm

-160dBm Typical value

≤- 128dBm

-140dBm Typical value

≤- 148dBm

-160dBm Typical value

Preamp on ≤- 130dBm ≤- 110dBm ≤- 130dBm
Level display range
Log scale 10 dB to 100 dB, 10 divisions displayed; 1, 2, 5, 10 dB/division
Linear scale 0% to 100%, 10 divisions displayed
Scale units dBm, dBmV, dBuV, dBuV/m, uV, mV, V, mW, W
Sweep (trace) points: 501
Marker level readout resolution:
Log scale 0.01 dB
Linear scale ≤1% of signal level Nominal
Detectors Normal, Positive peak, Sample, Negative peak
Number of traces: 3
Level display range
Trace functions: Clear/write, Maximum hold, Minimum hold, View
Level measurement error ±(0.6 dB + frequency response ), all frequency
Frequency response ±1dB
Reference level
Setting range -110 dBm to +30 dBm Steps of 1 dB
Setting resolution Log scale 0.01 dB
Linear scale Same as log (2.236 µV to 7.07 V)
Accuracy 0
RF Input VSWR (at tuned frequency)
< 1.5:1, (10 MHz to 3 GHz, 10 dB or 20 dB attenuation)
Spurious response
Second harmonic distortion < -70dBc, (Mixer signal level at -40 dBm, input attenuation 0 dB, preamp off)
Third order intermodulation distortion: < -70dBc,(Two -30 dBm tones at input mixer, spaced by 1MHz, input attenuation 0 dB, preamp off)
Input related spurious: < -60dBc, (-30 dBm signal at input mixer)
Inherent residual response: <-88dBm, (Input terminated 50? and 0dB RF attenuation, preamplifier off)
Sweep specifications
Sweep time
Range 10ms to 1000s, Span≥100 Hz;10µs to 100s, Span = 0 Hz (zero span)
Sweep mode Continuous, single
Trigger source Free run, Line trigger, External trigger
Trigger slope Positive or Negative edge available
RF input
Connector and impedance Type-N female, 50Ω Nominal
10 MHz reference
Reference input frequency 10 MHz
Reference input amplitude -10 dBm to +10 dBm
Reference output frequency 10 MHz
Reference output amplitude 0 dBm to +10 dBm
Connector BNC female, 50Ω Nominal
Auto Measurement Functions
Phase noise, Adjacent channel power, Occupied bandwidth.

Third order intermodulation distortion, Pass/Fail, Standing wave ratio.

Interface
Host connector USB Type-A female,
Device connector USB Type-mini AB female, LAN, RS232, VGA
General specifications
Display
Resolution 800 pixels x 480 pixels
Size and type 8.5 inch TFT color display
Languages On-screen GUI: English, Simplified Chinese
Power requirements
Adaptor voltage 100 V to 240 V AC, Rate 50/60/400 Hz , Auto-ranging
Power consumption less than 35W
Environmental and size
Temperature range 0 °C to +40 °C (Operating)

-40 °C to +70 °C (Storage)

Relative humidity < 95%
Weight less than 7kg
Dimensions 410 mm × 210mm × 136 mm, Approximately (W x H x D)
Tracking generator (Optional)
Frequency range 5MHz ~ 1.5 GHz 5MHz ~ 3 GHz 5MHz ~ 7.5 GHz
Output level 0 dBm to -25 dBm, 1 dB steps
Output flatness ±3dB
VSWR < 2.0: 1, Nominal
Connector and impedance Type-N female, 50 Ω
AM / FM Demodulation Measurement-except GA4032 (Optional)
AM Demodulation
Modulation Frequency 20Hz~100kHz
Frequency Accuracy 1Hz(Modulation Frequency<1kHz)

0.1%(Modulation Frequency≥1kHz)

Modulation Depth 5~95%
Depth Measurement Precision ±4%
FM Demodulation
Modulation Frequency 20Hz~200kHz
Frequency Accuracy 1Hz(Modulation Frequency<1kHz)

0.1%(Modulation Frequency>1kHz)

Frequency Offset 20Hz~400kHz
Frequency Offset Precision ±4%
SINAD
Measurement Range 0~60dBc
Measurement Precision ±1dB

For more detail, please download the brochure as above

Product Description

Product Overview
GA40XX series is a small size, light weight, cost-effective portable spectrum analyzer to meet your all the
RF application demands. It has easy-to-keyboard layout and high-definition 8.5-inch TFT color
LCD display; display contains the appropriate settings and alerts. It includes the standard USB, LAN and
RS232 communication interface, virtual terminal display and control and remote network access.
The spectrum analyzer can be widely applied in many fields of science education, enterprise
research and development and industrial production.

Features
Frequency range 9 kHz to 1.5GHz / 3GHz / 7.5GHz
Displayed average noise level (DANL)
GA4062/GA4032 9KHz~1.5GHz
GA4033/GA4062 9KHz~3GHz
Ga4064 9KHz~7.5GHz

TECHNICAL SPECIFICATIONS
GA4062 GA4032 GA4033 GA4063 GA4064
Frequency Specifications
Frequency range: 9 kHz to 1.5 GHz 9 kHz to 3 GHz 9 kHz to 7.5 GHz
Internal 10 MHz frequency reference accuracy
Initial Calibration accuracy ± 1 x 10 -7
Aging rate: ± 0.1ppm/yr ± 1ppm/year ± 0.1ppm/yr
Temperature stability: ± 5 x 10 -8 ppm – Referenced to frequency reading at 0-50 °C.
Frequency readout accuracy with marker (start, stop, center, marker)
Marker resolution:  (frequency span)/(sweep points -1),
Uncertainty ± (frequency indication × frequency reference uncertainty +1% × span +10% ×resolution bandwidth + marker resolution+1 Hz)
Frequency reference uncertainty = (aging rate x period of time since adjustment + temperature stability).
Marker frequency counter
Resolution 1 Hz
Accuracy ±(marker frequency × frequency reference uncertainty +counter resolution)
(marker level to displayed noise level > 25 dB; frequency offset 0 Hz)
Frequency span
Range 0Hz (zero span), 100 Hz to 3GHz
Resolution 1 Hz
Accuracy ±span/(sweep points -1)
SSB phase noise < -100 dBc/Hz, Carrier offset 100 kHz < -90 dBc/Hz, Carrier offset 10 kHz < -95 dBc/Hz, Carrier offset 10 kHz
(Center frequency 500 MHz, RBW= 100Hz, VBW=1Hz, Operating Temp: 20 °C to 30 °C).
Resolution bandwidth (RBW)
-3 dB bandwidth: 1 Hz to 3 MHz 1 Hz to 1 MHz 1 Hz to 3 MHz
Accuracy: ± 5%, RBW = 10 Hz to 1 MHz Nominal, ±10%, RBW = 3 MHz
Resolution filter shape factor < 5 : 1
Video bandwidth (VBW)
-3 dB bandwidth 1 Hz to 3 MHz, 1-3-10 sequence
Amplitude
Measurement range +30dBm to displayed average noise level (DANL)
Input attenuator range 0 dB to 50 dB, in 10 dB steps.
Maximum safe input level
Average continuous power +30 dBm, (3 minutes maximum, Input attenuator≥20 dB, preamplifier off
DC voltage ± 50 VDC maximum ± 25 VDC maximum
Displayed average noise level
Preamp off ≤- 148dBm

-160dBm Typical value

≤- 128dBm

-140dBm Typical value

≤- 148dBm

-160dBm Typical value

Preamp on ≤- 130dBm ≤- 110dBm ≤- 130dBm
Level display range
Log scale 10 dB to 100 dB, 10 divisions displayed; 1, 2, 5, 10 dB/division
Linear scale 0% to 100%, 10 divisions displayed
Scale units dBm, dBmV, dBuV, dBuV/m, uV, mV, V, mW, W
Sweep (trace) points: 501
Marker level readout resolution:
Log scale 0.01 dB
Linear scale ≤1% of signal level Nominal
Detectors Normal, Positive peak, Sample, Negative peak
Number of traces: 3
Level display range
Trace functions: Clear/write, Maximum hold, Minimum hold, View
Level measurement error ±(0.6 dB + frequency response ), all frequency
Frequency response ±1dB
Reference level
Setting range -110 dBm to +30 dBm Steps of 1 dB
Setting resolution Log scale 0.01 dB
Linear scale Same as log (2.236 µV to 7.07 V)
Accuracy 0
RF Input VSWR (at tuned frequency)
< 1.5:1, (10 MHz to 3 GHz, 10 dB or 20 dB attenuation)
Spurious response
Second harmonic distortion < -70dBc, (Mixer signal level at -40 dBm, input attenuation 0 dB, preamp off)
Third order intermodulation distortion: < -70dBc,(Two -30 dBm tones at input mixer, spaced by 1MHz, input attenuation 0 dB, preamp off)
Input related spurious: < -60dBc, (-30 dBm signal at input mixer)
Inherent residual response: <-88dBm, (Input terminated 50? and 0dB RF attenuation, preamplifier off)
Sweep specifications
Sweep time
Range 10ms to 1000s, Span≥100 Hz;10µs to 100s, Span = 0 Hz (zero span)
Sweep mode Continuous, single
Trigger source Free run, Line trigger, External trigger
Trigger slope Positive or Negative edge available
RF input
Connector and impedance Type-N female, 50Ω Nominal
10 MHz reference
Reference input frequency 10 MHz
Reference input amplitude -10 dBm to +10 dBm
Reference output frequency 10 MHz
Reference output amplitude 0 dBm to +10 dBm
Connector BNC female, 50Ω Nominal
Auto Measurement Functions
Phase noise, Adjacent channel power, Occupied bandwidth.

Third order intermodulation distortion, Pass/Fail, Standing wave ratio.

Interface
Host connector USB Type-A female,
Device connector USB Type-mini AB female, LAN, RS232, VGA
General specifications
Display
Resolution 800 pixels x 480 pixels
Size and type 8.5 inch TFT color display
Languages On-screen GUI: English, Simplified Chinese
Power requirements
Adaptor voltage 100 V to 240 V AC, Rate 50/60/400 Hz , Auto-ranging
Power consumption less than 35W
Environmental and size
Temperature range 0 °C to +40 °C (Operating)

-40 °C to +70 °C (Storage)

Relative humidity < 95%
Weight less than 7kg
Dimensions 410 mm × 210mm × 136 mm, Approximately (W x H x D)
Tracking generator (Optional)
Frequency range 5MHz ~ 1.5 GHz 5MHz ~ 3 GHz 5MHz ~ 7.5 GHz
Output level 0 dBm to -25 dBm, 1 dB steps
Output flatness ±3dB
VSWR < 2.0: 1, Nominal
Connector and impedance Type-N female, 50 Ω
AM / FM Demodulation Measurement-except GA4032 (Optional)
AM Demodulation
Modulation Frequency 20Hz~100kHz
Frequency Accuracy 1Hz(Modulation Frequency<1kHz)

0.1%(Modulation Frequency≥1kHz)

Modulation Depth 5~95%
Depth Measurement Precision ±4%
FM Demodulation
Modulation Frequency 20Hz~200kHz
Frequency Accuracy 1Hz(Modulation Frequency<1kHz)

0.1%(Modulation Frequency>1kHz)

Frequency Offset 20Hz~400kHz
Frequency Offset Precision ±4%
SINAD
Measurement Range 0~60dBc
Measurement Precision ±1dB

For more detail, please download the brochure as above

Category



Newsletter