+6012-2100 344


Name:   Password:

Products

Tenmars TM-411 Air Velocity Meter

ENQUIRY




Download Brochure

Anemometer
Model: TM-411~414

Product Description

– 45mm 4 plastics vane
– High sensitivity of 0.4m/s.
– Air flow calculates function.
– Max/Min/Avg and data hold.
– Auto power off with disable function.
– Memory capacity: 99 records.
– Memory recall function.
– Backlight function.
– Absolute Pressure Sensor
– Humidity Sensor

TM-41X series measures air speed, temperature and humidity. It is ideal for spot measurements

at air outlets on account of its 30mm vane. In addition to air speed and temperature, also measures air moisture and absolute pressure. In this way, air conditions can be reliably checked.

Four models:

MODEL# Velocity 99 Record Flow Temperature Humidity Pressure
TM-411 V V V  —
TM-412 V V V V  —
TM-413 V V V V V  
TM-414 V V V V V V

Velocity (Air Speed):

Unit Range Resolution Accuracy
m/s 0.4~30 0.1 ±3%+0.2
Km/hr(kph) 1.5~106 0.1 ±3%+0.8
mph 0.9~66 0.1 ±3%+0.4
Knots(kts) 0.8~58 0.1 ±3%+0.4
ft/min(fpm) 79~5866 1 ±3%+40
Beaufort 1~8 1

 

Air Flow Calculation:

Unit Range Resolution Accuracy
CMM 0~9999 1
CFM 0~9999 1

 

 

Temperature:

Unit Range Resolution Accuracy
°C -20~60 0.1 ±1 °C
°F -4~140 0.1 ±1.8°F

 

Humidity:

Unit Range Resolution Accuracy
%RH 20~80 0.1 ±3.5%RH
%RH 80 0.1 ±5%RH

 

Absolute Pressure:

Unit Range Resolution Accuracy
hPa 350~1100 0.1 ±2hPa
mmHg 263~825 0.1 ±1.5mmHg
inHg 10.3~32 0.1 ±0.1

 

Product Description

Product Description

– 45mm 4 plastics vane
– High sensitivity of 0.4m/s.
– Air flow calculates function.
– Max/Min/Avg and data hold.
– Auto power off with disable function.
– Memory capacity: 99 records.
– Memory recall function.
– Backlight function.
– Absolute Pressure Sensor
– Humidity Sensor

TM-41X series measures air speed, temperature and humidity. It is ideal for spot measurements

at air outlets on account of its 30mm vane. In addition to air speed and temperature, also measures air moisture and absolute pressure. In this way, air conditions can be reliably checked.

Four models:

MODEL# Velocity 99 Record Flow Temperature Humidity Pressure
TM-411 V V V  —
TM-412 V V V V  —
TM-413 V V V V V  
TM-414 V V V V V V

Velocity (Air Speed):

Unit Range Resolution Accuracy
m/s 0.4~30 0.1 ±3%+0.2
Km/hr(kph) 1.5~106 0.1 ±3%+0.8
mph 0.9~66 0.1 ±3%+0.4
Knots(kts) 0.8~58 0.1 ±3%+0.4
ft/min(fpm) 79~5866 1 ±3%+40
Beaufort 1~8 1

 

Air Flow Calculation:

Unit Range Resolution Accuracy
CMM 0~9999 1
CFM 0~9999 1

 

 

Temperature:

Unit Range Resolution Accuracy
°C -20~60 0.1 ±1 °C
°F -4~140 0.1 ±1.8°F

 

Humidity:

Unit Range Resolution Accuracy
%RH 20~80 0.1 ±3.5%RH
%RH 80 0.1 ±5%RH

 

Absolute Pressure:

Unit Range Resolution Accuracy
hPa 350~1100 0.1 ±2hPa
mmHg 263~825 0.1 ±1.5mmHg
inHg 10.3~32 0.1 ±0.1

 