Product Description
Features
.20MHz/30MHz/40MHz dual channel
.High sensitivity 1mV/DIV
.Wide vertical range 20V/DIV
.TV synchronization
.Z axis input
.Vertical mode triggering
.CH 1 output
Technical Data | CQ5020/CQ5030/CQ5040 | ||||
CRT | |||||
Type | 6″ rectangle, internal graticule, 0%, 10%, 90% and 100% marks | ||||
Display area | 8 x 10DIV (DIV=10mm) | ||||
Accelerating voltage | .9kV(CQ5020) 2kV (CQ5030)12kV(CQ5040) | ||||
Intensity and focusing | Continuously adjustable at front panel | ||||
Trace rotation | Adjusted at the front panel | ||||
VERTICAL SYSTEM | |||||
Sensitivity and accuracy | 5mV / DIV~20V / DIV ±3% 1mV / DIV ~ 2mV / DIV, ±5% 12 calibration steps in 1-2-5 sequence, x 5 MAG only CH1 |
||||
Trimming ratio | ≥2.5:1 | ||||
Width of band (-3dB) | DC(AC 10Hz) ~20MHz (CQ5020) | ||||
DC(AC 10Hz) ~30MHz (CQ5030) | |||||
DC(AC 10Hz) ~40MHz (CQ5040) | |||||
Rise Time | ≤17.5ns (CQ5020) | ||||
≤12ns (CQ5030) | |||||
≤8.75ns (CQ5040) | |||||
Max. Input Voltage | 400V (DC + ACpeak) at 1kHz or less | ||||
Input Coupling | AC, DC, GND | ||||
Input Impedance | Approx. 1MΩ±3% 30pF±5pF | ||||
Vertical Mode | CH1, CH2, DUAL (CHOP, ALT) ADD, CH2 inverse | ||||
CH1 signal output | 25mV / DIV 50? 20Hz~10MHz(-3dB) | ||||
HORIZONTAL SYSTEM | |||||
Sweep time | 0.2us~0.2s / DIV 19 steps in 1-2-5 sequence | ||||
Sweep accuracy | ±3%, ±5% at x10MAG | ||||
Trimming ratio | ≥2.5:1 | ||||
Sweep magnificaton | x10MAG | ||||
Max sweep time | 20nS/DIV | ||||
TRIGGER SYSTEM | |||||
Trigger Modes | AUTO,NORM,TV | ||||
Trigger Source | VERT-MODE, CH1, EXT, LINE | ||||
Coupling | AC | ||||
Trigger Polarity | “+” or “-“ | ||||
Trigger sensitivity | 1 | 10Hz~10MHz | 10MHz~20MHz | 20MHz~30MHz | 30MHz~40MHz |
INT | 0.5DIV | 1.5DIV | 1.5DIV | 1.5DIV | |
EXT | 0.2 | 0.8 | 0.2 | 0.8 | |
TV sync pulse 1 DIV or 1V (EXT) | |||||
External trigger input | Input impedance: 1MΩ±3% 25pF±5pF | ||||
Max. input voltage: 400V | |||||
X-Y OPERATION | |||||
Input | X-axis: CH1, Y-axis: CH2 | ||||
Sensitivity & accuracy | 5mV~20V/DIV, ±3% 1mV/DIV~2mV/DIV, ±5% | ||||
Width of band (-3dB) | Axis X: CQ5020: DC ~ 500kHz CQ5030: DC ~ 1MHz CQ5040: DC ~ 1MHz | ||||
Phase difference | ≤3 or less from DC to 50kHz) | ||||
Axis Z | |||||
Sensitivity | 5V | ||||
Polarity | Negative going input increase intensity | ||||
Input impedance | 20KΩ~30KΩ | ||||
Usable frequency range | DC~2MHz | ||||
Max. input voltage | 30V (DC+AC peak) | ||||
CALIBRATION | |||||
Signal | 1kHz 0.5Vp-p square wave | ||||
POWER SOURCE | 110~127 VAC±10%, 220~240VAC±10%, 50Hz±2Hz / 60Hz±2Hz | ||||
ACCESSORIES |
Instruction manual x 1, Power cable x 1 ,Fuse x 1, Probe x 2 | ||||
DIMENSIONS & WEIGHT | 316mm x 132mm x 410mm, Approx 7.8kg |