Product Description
MPS-3002L-3 / 3003L-3 / 3003LK-3 / 3005L-3 / 3005LK-3 |
|||
Multi-ouput Adjustable DC Power Supply with Fixed 5V/3A Output |
|||
Model
|
Output
|
Fixed 5V/3A output
|
Output Standby Function
|
MPS-3002L-3
|
30V/2A
|
YES
|
NO
|
MPS-3003L-3
|
30V/3A
|
YES
|
NO
|
MPS-3005L-3
|
30V/5A
|
YES
|
NO
|
MPS-3003L-3
|
30V/3A
|
YES
|
YES
|
MPS-3005LK-3
|
30V/5A
|
YES
|
YES
|
- Main Power Supply: 220V±10%, 50/60Hz±2Hz; 110/220V±10% selectable, 50/60Hz±2Hz (customer optional)
- Rating
- Output Voltage: 0-30V
- Maximum output current: 0~2A/3A/5A
- Operation Mode
- Independent: Two independent outputs+5V/3A fixed output. Output from 0V tomax. rating voltage and from 0A to max. rating current.
- Series:0~60V / 2A / 3A / 5A
- Parallel: 0~30V / 4A / 6A / 10A
- Voltage
- Line regulation: CV≤ 0.01%+3mV; CC≤ 0.2%+3mA
- Load regulation: CV≤ 0.01%+3mV(rating current ≤ 3A), CC≤ 0.2%+3mA (tating current≤3A )
- Load regulation: CV≤ 0.02%+5mV(rating current >3A), CC≤ 0.2%+5mA (tating current>3A )
- Recovery tim:e ≤ 100 μ S
- Ripple & noises: CV≤ 3mV rms
- Temperature coefficient ≤ 300ppm/ ℃
- Constant Current Operation
- Output current range: 0A~rating current continuously adjustable
- Current
- Line regulation: CC≤ 0.2%+3mA
- Load regulation: CC≤ 0.2%+3mA
- Ripple & noise: CC≤ 3mA rms
- Tracking Operation
- Parallel operation:
- Line regulation ≤ 0.01%+3mV;
- Load regulation ≤ 0.01%+3mV(rating current ≤ 3A);
- ≤ 0.02%+5mV(rating current3A)
- Series operation:
- Line regulation ≤ 0.01%+5mV;
- Load regulation ≤ 300mV
- Positive and Negative supply:
- Slave tracking error ≤ 0.5%+10mV of the master (No load; if load, please add load regulation ≤ 300mV)
- Meter
- Voltage dispaly: 3 and 1/2 Digits panel meter; Accuracy: ( ± 0.51% of rdg +2 digits)
- Current display: 3 and 1/2 Digits panel meter: Accuracy: ( ± 1% of rdg +2 digits)
- Fixed 5V/3A Output Specifications
- Voltage accuracy: 5V±0.25V
- Output current: 3A
- Regulation: Line regulation ≤ 5mV, Load regulation ≤ 15mV
- Ripple&Noise ≤ 2mV rms
- Protection: current limit and short circuit protection
- Operation Temperature & Humidity 0 ℃ to 40 ℃/ <80%
- Storage Temperature & Humidity -100 ℃ to 70 ℃ / <70%
- Working house: moe than 8 hours, 80% load
- 0-30V, 0-2A/3A/5A Dual Channels adjustable and one fixed 5V/3A output
- Overload Protection
- Constant Voltage, Constant Current, Low ripple noise, Low temperature drift
- Pre-set current limited point
- In tracking mode, both outputs are automatically connected in series or parallel without extra cables
- In series mode, machine can be connected as positive and negative supply
- Multi tune potentiometers, easy to setup voltage
- High efficient toroidal transformer
- Dual Color four LED Digital Panel Meters Voltages and Current Display
- MPS-3003LK-3 / MPS-3005L-3 have output standby function