DU-6211 Programmable LCRZ Meter

ENQUIRY




Download Brochure

Programmable LCRZ Meter ( 10KHz )
Model: DU-6211

 

 

Feature
Wide Measuring Range & High accuracy 0.1%
Zeroing Offset Function
Provided HI/LOW limit and BIN Sorting comparator function, to meet your needed.
100 sets of memory, can be saved test parameter and comparator setting, easy to use.
Cover up free, system firmware upgrade can be update via RS-232, easy to maintenance
Easy Test Condition Setting with Auto Parameter Selection & Auto Ranging Function
High speed FADC, max. test speed up to 75 meas./sec, faster your automation equipment
240*64 Graphic LCD display, can be read the reading clearly and easier.
User friendly programmable interface, easy to use
Provided RS-232C and Handler combinatorial interface option, to meet your needed
Specification
Model DU-6211
Parameter L.C.R.Z.Q.D.ESR.θ
Test Frequency 100Hz、120Hz、1KHz、10KHz
Test Voltage 0.1V、0.25V、0.5V、1.00V,(± 5% + 5mV)
Measurement
Accuracy
Basic accuracy ± 0.1 %
Measurement
Range
L: 0.1 uH ~ 1999.9H           Q: 0.01~ 1999.9
C: 0.1 pF ~ 199.99mF          D: 0.0001~ 19.999
R: 0.1 mΩ ~ 19.999 MΩ       θ: -180°~ +180
Z: 0.1 mΩ ~ 199.99 MΩ      ESR: 0.1 mΩ ~ 19.999 MΩ
Test Speed SLOW:400ms   MED: 150ms    FAST: 75ms
Trigger Mode Internal、External
Comparator Auto parameter, Auto ranging, Zeroing calibration
Comparator HI/LO Limit
R standard value & Hi-Lo % limits. OK/NG Judgment & indication with alarm.
BIN Sorting
9 Bins for sorting. R standard value & Hi-Lo % limits. OK/NG Judgment & indication with alarm.
Display LCD 240 x 64 Graphic display, 4 1/2 digits
Memory Up to 100 sets of memory
Interface RS-232 & Handler Two interface features combined together (Option)
Backup status Measurement status : Measure range, Parameter, Frequency, Circuit (Parallel / Series)
                Voltage, Comparator setting
Calibration Software and adjustments are made through the front panel. Automatic Calibration
Alert function to signal operator when re-calibration is due.
Power 115V/230 V ± 10%, 50/60 Hz
Dimensions 270(W) x 110(H) x 310(D) mm
Security Programmable password lockout capability to avoid unauthorized access to test set-up program
Equipment status Model、S/N Number、Software Version、Calibration Mode、Calibration Date
Calibration Result、Check Date、Check Result Etc.
Order Information
DU-6211
LCR Meterr
Standard Fittings
Fx60-0101
LCR Test Clips
Optional Accessories
Fx60-0201
Double-Sided Test Box
Fx60-0202
One-sided Test box
Cr60-RSHD
RS232/HANDLER combinatorial interface
Fx60-0101
Fx60-0201
Cr60-RSHD

 

 

Product Description

 

 

Feature
Wide Measuring Range & High accuracy 0.1%
Zeroing Offset Function
Provided HI/LOW limit and BIN Sorting comparator function, to meet your needed.
100 sets of memory, can be saved test parameter and comparator setting, easy to use.
Cover up free, system firmware upgrade can be update via RS-232, easy to maintenance
Easy Test Condition Setting with Auto Parameter Selection & Auto Ranging Function
High speed FADC, max. test speed up to 75 meas./sec, faster your automation equipment
240*64 Graphic LCD display, can be read the reading clearly and easier.
User friendly programmable interface, easy to use
Provided RS-232C and Handler combinatorial interface option, to meet your needed
Specification
Model DU-6211
Parameter L.C.R.Z.Q.D.ESR.θ
Test Frequency 100Hz、120Hz、1KHz、10KHz
Test Voltage 0.1V、0.25V、0.5V、1.00V,(± 5% + 5mV)
Measurement
Accuracy
Basic accuracy ± 0.1 %
Measurement
Range
L: 0.1 uH ~ 1999.9H           Q: 0.01~ 1999.9
C: 0.1 pF ~ 199.99mF          D: 0.0001~ 19.999
R: 0.1 mΩ ~ 19.999 MΩ       θ: -180°~ +180
Z: 0.1 mΩ ~ 199.99 MΩ      ESR: 0.1 mΩ ~ 19.999 MΩ
Test Speed SLOW:400ms   MED: 150ms    FAST: 75ms
Trigger Mode Internal、External
Comparator Auto parameter, Auto ranging, Zeroing calibration
Comparator HI/LO Limit
R standard value & Hi-Lo % limits. OK/NG Judgment & indication with alarm.
BIN Sorting
9 Bins for sorting. R standard value & Hi-Lo % limits. OK/NG Judgment & indication with alarm.
Display LCD 240 x 64 Graphic display, 4 1/2 digits
Memory Up to 100 sets of memory
Interface RS-232 & Handler Two interface features combined together (Option)
Backup status Measurement status : Measure range, Parameter, Frequency, Circuit (Parallel / Series)
                Voltage, Comparator setting
Calibration Software and adjustments are made through the front panel. Automatic Calibration
Alert function to signal operator when re-calibration is due.
Power 115V/230 V ± 10%, 50/60 Hz
Dimensions 270(W) x 110(H) x 310(D) mm
Security Programmable password lockout capability to avoid unauthorized access to test set-up program
Equipment status Model、S/N Number、Software Version、Calibration Mode、Calibration Date
Calibration Result、Check Date、Check Result Etc.
Order Information
DU-6211
LCR Meterr
Standard Fittings
Fx60-0101
LCR Test Clips
Optional Accessories
Fx60-0201
Double-Sided Test Box
Fx60-0202
One-sided Test box
Cr60-RSHD
RS232/HANDLER combinatorial interface
Fx60-0101
Fx60-0201
Cr60-RSHD

 

 

Category