CQ6103 Analog Oscilloscope

ENQUIRY




Download Brochure

100MHz Analog Oscilloscope
Model: CQ6103

100MHz DUAL CHANNEL OSCILLOSCOPE

Features
.100MHz bandwidth, dual channel, delayed sweep
.10 sets memory for front panel setting save & recall
.Cursor readout with 7 measurements
.Panel setup lock of digital-control functions
.Buzzer alarm
.Trigger signal output
.Z-Axis modulation input
.SMD technology, high stability and reliability

Technical Data CQ6103
CRT
Type 6″ rectangle, internalgraticule, 0%, 10%, 90% and 100% marks
Display area 8 x10DIV (DIV=10mm)
Accelerating potential 16kV approx
Illumination Continuously adjustable at front panel
Z-axis input Coupling: DC
Sensitivity: 5V or more
Maximum input voltage:30V(DC+AC peak) at 1kHz or less
Bandwidth: DC~5MHz
VERTICAL SYSTEM
Sensitivity 2mV~5V/DIV, 11 steps in 1-2-5 sequence
Sensitivity accuracy ≤3% (5 div at the center of display)
Vernier vertical sensitivity Countinuously variabble to 1/2.5 or less of panel-indicate value
Width of band (-3dB) DC ~100MHz(2mV/div: DC~20MHz)
Rise time 3.5ns (2mV/div:17.5ns)
Singal delay Leading edge can be monitored
Input Coupling AC, DC, GND
Input Impedance 1Mμ±2% / Approx 25pF
Vertical mode CH1, CH2, DUAL(CHOP/ALT), ADD, CH2 INV
Bandwidth limited 20MHz
Common-mode rejection ratio 50:1 or better at 50kHz
Dynamic range 8 div at 100MHz
HORIZONTAL SYSTEM
Horizontal modes MAIN(A), ALT, DELAY(B)
A(main) sweep time
50nS~0.2S/div, continuously variable(UNCAL)
B(delay) sweep time 50ns~50ms/div
Sweep accuracy ±3%, ±5% at x10MAG
Sweep magnificaton x10MAG (maximum sweep time 5ns/div)
Delay time 1us~5s
Delay jitter Better than 1:20000
Alternate separation Variable
TRIGGER
Mode AUTO, NORM, TV
Source CH1, CH2, EXT, LINE
Coupling AC, DC, HFR, LFR
Slope “+” or “-” polarity or TV sync polarity
Trigger sensitivity Mode       Frequency INT EXT
Auto    10Hz~20Mhz
20MHz~100MHz
0.35div
1.5div
50mV
150mV
Norm DC~20MHz
20MHz~100MHz
0.35div
1.5div
50mV
150mV
TV

sync signal 1div 200mVpp
TV sync TV-V, TV-H
Max external input voltage 400V(DC+AC peak) at 1kHz
External input impedance 1Mμ±5% / approx. 25pF
X-Y OPERATION
Mode X-axis: selectable CH1, CH2, EXT
Y-axis: selectable CH1, CH2, CH1 and CH2
Sensitivity and Accuracy 2mV~5V/DIV, ±3%; EXT:0.1V/div±5%
X-axis bandwidth DC~500kHz(-3dB)
Phase Error 3° or less from DC~50kHz
OUTPUT SIGNAL
Trigger signal output Voltage: approx.25mV/div into 50Ω
Frequency response: DC~10MHz
Calibrator output 1kHz square wave, 2Vpp±2%
CURSOR READOUT FUNCTION
Cursor measurement function AV, AV%, AVdB, AT, 1/AT, AT%, Aѐ
Cursor resolution 1/100 DIV
Effective cursor range Vertical:±3 div; Horizontal: ±4 div
Panel setting display Vertical: V/div(CH1, CH2), UNCAL, ALT/CHOP/ADD, INV, probe
factor, AC/DC/GND
Horizontal: s/div(MTB,DTB), UNCAL, x10MAG, delay time, HO
Trigger: source, coupling, slope, level, TV-V, TV-H
Others: X-Y, lock, save/recall MEM 0-9
SPECIAL FUNCTION
TIME/DIV Auto range Provided
Panel setting save & recall 10 sets
Panel setups lock Provided
POWER SOURCE 110~127 VAC±10%, 220~240VAC±10%, 50Hz±2Hz / 60Hz±2Hz
ACCESSORIES Instruction manual x 1, Power cable x 1, Probe x 2  ,Fuse x1
DIMENSIONS & WEIGHT 10(W) x 140(H) x 400(D)mm, Approx. 8kg

For more detail, please download brochure as above

Product Description

100MHz DUAL CHANNEL OSCILLOSCOPE

Features
.100MHz bandwidth, dual channel, delayed sweep
.10 sets memory for front panel setting save & recall
.Cursor readout with 7 measurements
.Panel setup lock of digital-control functions
.Buzzer alarm
.Trigger signal output
.Z-Axis modulation input
.SMD technology, high stability and reliability

Technical Data CQ6103
CRT
Type 6″ rectangle, internalgraticule, 0%, 10%, 90% and 100% marks
Display area 8 x10DIV (DIV=10mm)
Accelerating potential 16kV approx
Illumination Continuously adjustable at front panel
Z-axis input Coupling: DC
Sensitivity: 5V or more
Maximum input voltage:30V(DC+AC peak) at 1kHz or less
Bandwidth: DC~5MHz
VERTICAL SYSTEM
Sensitivity 2mV~5V/DIV, 11 steps in 1-2-5 sequence
Sensitivity accuracy ≤3% (5 div at the center of display)
Vernier vertical sensitivity Countinuously variabble to 1/2.5 or less of panel-indicate value
Width of band (-3dB) DC ~100MHz(2mV/div: DC~20MHz)
Rise time 3.5ns (2mV/div:17.5ns)
Singal delay Leading edge can be monitored
Input Coupling AC, DC, GND
Input Impedance 1Mμ±2% / Approx 25pF
Vertical mode CH1, CH2, DUAL(CHOP/ALT), ADD, CH2 INV
Bandwidth limited 20MHz
Common-mode rejection ratio 50:1 or better at 50kHz
Dynamic range 8 div at 100MHz
HORIZONTAL SYSTEM
Horizontal modes MAIN(A), ALT, DELAY(B)
A(main) sweep time
50nS~0.2S/div, continuously variable(UNCAL)
B(delay) sweep time 50ns~50ms/div
Sweep accuracy ±3%, ±5% at x10MAG
Sweep magnificaton x10MAG (maximum sweep time 5ns/div)
Delay time 1us~5s
Delay jitter Better than 1:20000
Alternate separation Variable
TRIGGER
Mode AUTO, NORM, TV
Source CH1, CH2, EXT, LINE
Coupling AC, DC, HFR, LFR
Slope “+” or “-” polarity or TV sync polarity
Trigger sensitivity Mode       Frequency INT EXT
Auto    10Hz~20Mhz
20MHz~100MHz
0.35div
1.5div
50mV
150mV
Norm DC~20MHz
20MHz~100MHz
0.35div
1.5div
50mV
150mV
TV

sync signal 1div 200mVpp
TV sync TV-V, TV-H
Max external input voltage 400V(DC+AC peak) at 1kHz
External input impedance 1Mμ±5% / approx. 25pF
X-Y OPERATION
Mode X-axis: selectable CH1, CH2, EXT
Y-axis: selectable CH1, CH2, CH1 and CH2
Sensitivity and Accuracy 2mV~5V/DIV, ±3%; EXT:0.1V/div±5%
X-axis bandwidth DC~500kHz(-3dB)
Phase Error 3° or less from DC~50kHz
OUTPUT SIGNAL
Trigger signal output Voltage: approx.25mV/div into 50Ω
Frequency response: DC~10MHz
Calibrator output 1kHz square wave, 2Vpp±2%
CURSOR READOUT FUNCTION
Cursor measurement function AV, AV%, AVdB, AT, 1/AT, AT%, Aѐ
Cursor resolution 1/100 DIV
Effective cursor range Vertical:±3 div; Horizontal: ±4 div
Panel setting display Vertical: V/div(CH1, CH2), UNCAL, ALT/CHOP/ADD, INV, probe
factor, AC/DC/GND
Horizontal: s/div(MTB,DTB), UNCAL, x10MAG, delay time, HO
Trigger: source, coupling, slope, level, TV-V, TV-H
Others: X-Y, lock, save/recall MEM 0-9
SPECIAL FUNCTION
TIME/DIV Auto range Provided
Panel setting save & recall 10 sets
Panel setups lock Provided
POWER SOURCE 110~127 VAC±10%, 220~240VAC±10%, 50Hz±2Hz / 60Hz±2Hz
ACCESSORIES Instruction manual x 1, Power cable x 1, Probe x 2  ,Fuse x1
DIMENSIONS & WEIGHT 10(W) x 140(H) x 400(D)mm, Approx. 8kg